City of Pembroke Pines (FL)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2023 8TH EDITION FLORIDA BUILDING CODE: BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL
2023 8TH EDITION FLORIDA BUILDING CODE: MECHANICAL
2023 8TH EDITION FLORIDA BUILDING CODE: PLUMBING
2023 8TH EDITION FLORIDA BUILDING CODE: FUEL GAS
2023 8TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION
2023 8TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY
2023 8TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA)
ASCE 7-22
2020 NATIONAL ELECTRIC CODE (NEC)
- ASCE Code Specification
- ASCE 7-22
SolarAPP+ & submittal
- How Many Plansets Required
- 2
- Revision Required
- 1
- Rough Inspection
- Footing inspection
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
FL statute letter required
Digitally Verified Signature
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 170
- Wind Notes
Exposure Category C ; HVHZ
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
Special Inspector form needs to be requested from 3rd party SE, along with stamps. Use the form from the files below with Greg's signature pre-saved on it. Digital stamped pages in one PDF File
Digitally Verified Signature
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Load Side Taps,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
APPROVED PLANSET UPLOADED FOR CORRECT REFERENCE
Per branch: The go to sealant that needs to be used here is M1. Include spec sheet into the plans as required by the AHJ PROVIDE FLASHKIT SPECS and Sealant SPECS for all projects.
UL2703 Provide racking manufacturer's compatibility with modules and microinverters/optimizers
UPLOAD SIF TO LIGHTSPEED (SEE FILES)
- Attachment Detail
Do not use railless Comp Shingle - Unirac Flashkit Pro (spec sheet is named 2021 -NOA Unirac in file section below) Tile - Snap'n'Rack Tile Hook (spec sheet is named NOA SnapNrack in file section below) Per branch: The go to sealant that needs to be used here is M1. Include spec sheet into the plans as required by the AHJ
- Electrical Diagram
* If an MPU is required , AHJ would like to see photos of the interior panel (if applicable) As well as spec sheets for new MSP. * For Supply Side Connections, this note is required on Site Plan, Single Line Diagram, and AC Disco spec sheet: "AC DISCONNECT IS SUITABLE FOR USE AS SERVICE EQUIPMENT" * Equipment ground cannot be used on supply side connections * ELD must show meter can rating and service entrance conductors
Grounded conductor cannot be paralleled with EGC on a line side connection
AHJ requires the size of existing feeders to any subpanel be shown. If the subpanel is feed through lug feed from the MSP, a main breaker will need to be installed inside the subpanel.
Taps
- Do not list piercing taps for line side tap connections. The only fitting we can use for line side taps in these AHJs are insulated Polaris taps.
-Provide intersystem bonding termination at service and show on plans.
-Surge protection required for service supplying dwelling units, show on plan.
-PV SERVICE DISCONNECT; MUST BE SERVICE RATED, SHOW ON PLANS.
-SHOW THE (NEUTRAL) BAR AS BEING GROUNDED/BONDED TO THE ENCLOSURE AND THE GROUNDING BAR FOR LINE SIDE CONNECTIONS
-PROVIDE SIZE CONDUIT AND CONDUCTORS FOR CONDUIT BETWEEN THE EXISTING UTILITY METER AND MSP
- Label Page
FLORIDA - 2020 CAD BLOCK
- Custom Placards Required
- 1
- Non Standard Planset Requirements
- Single Line Diagram
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim