City of Oakland Park (FL)
Codes
- NEC Code Version
- 2020
- Code List
2023 8TH EDITION FLORIDA BUILDING CODE: BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL
2023 8TH EDITION FLORIDA BUILDING CODE: MECHANICAL
2023 8TH EDITION FLORIDA BUILDING CODE: PLUMBING
2023 8TH EDITION FLORIDA BUILDING CODE: FUEL GAS
2023 8TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION
2023 8TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY
2023 8TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA)
2020 NATIONAL ELECTRIC CODE (NEC)
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 2
- Revision Required
- 1
- Rough Inspection
- Footing inspection
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
EE cannot be swapped to a different EE.
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 167
- Wind Notes
Exposure Category C ; HVHZ
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
Special Inspector Form required (Use the template uploaded below) The engineer(s) stamping the plans must be consistent throughout the project. The SE or EE cannot be swapped to a different SE or EE.
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- Yes
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Supply Tap Neutral Ground Bond Required
- 1
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Need the installation instructions for PW3 and show a side view of the house (show distance between battery storage and other equipment, show the distance between battery storage and any openings in the house.) FBC 107.3.5B
Attach Backup Interface Spec Sheet to planset if building with SEEB in this AHJ
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
ATTACH SIF (SEE FILES)
PROVIDE RACKING GROUNDING DETAILS
- Site Notes
All Jobs [BOS to be 3ft away from irrigation lines]
- Roof Plan Notes
All Jobs [All bedrooms and common areas are equipped with smoke alarms per FS 553.883]
- Attachment Detail
M1 SEALANT FOR NON-TILE (ADD NOA IN FILES)
KARNAK SEALANT FOR TILE (ADD NOA IN FILES)
- Electrical Diagram
Piercing Taps NOT ALLOWED
USE Polaris taps
- Label Page
FLORIDA 2020 CAD BLOCK
- Custom Placards Required
- 1
- Non Standard Revision Requirements
SUBMIT ONLY REVISED PAGES FOR REVISIONS (ZIP FILE)
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim