City of Coconut Creek (FL)

Florida Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2020
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural,Digital Electrical
Fire Setback Enforced1

Codes

NEC Code Version
2020
Fire Code Version
2018 Building Code
Code List

2023 8TH EDITION FLORIDA BUILDING CODE: BUILDING 

2023 8TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL 

2023 8TH EDITION FLORIDA BUILDING CODE: MECHANICAL 

2023 8TH EDITION FLORIDA BUILDING CODE: PLUMBING 

2023 8TH EDITION FLORIDA BUILDING CODE: FUEL GAS 

2023 8TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION 

2023 8TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING 

2023 8TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY 

2021 8TH EDITION FLORIDA FIRE PREVENTION CODE, NFPA 1

2020 NATIONAL ELECTRIC CODE

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

How Many Plansets Required
1
Revision Required
1
Rough Inspection
Rough Electrical
New Planset Required For Module Swap
1

Stamps

Ee Stamp Required On SLD
Yes
Wet Stamps Required
Digital Structural,Digital Electrical
Structural Calculations Required
Yes
Ee Stamp Notes

Digitally Verified Signature

Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
1
Setback Notes


Structural & loads

Wind Speed
170
Wind Notes

Exposure Category C ; HVHZ

Snow Load
0
Reducible Snow Load Allowed
1
Max Attachment Spacing
48
Structural Notes

SE & EE digital stamps on all PV pages, FL Statute, PE Letter & Calcs. WS 170 MPH

STAMPED FILES MAY NOT EXCEED 15MB


Digitally Verified Signature

Minimum Ground On Roof
#10

Electrical

Electrical Load Calcs Required
Derates
Allowed POI
Load Side Taps,PV Breaker,Line Side Taps
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.96

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Standard

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Plan Set Requirements

APPROVED PLANSET UPLOADED FOR CORRECT REFERENCE

Planset PDF file must be in the smallest file size without layers.

Site Notes

All Jobs [Wind Speed: 170mph]

Roof Plan

SHOW ATTACHMENTS AND RAIL ON ROOF PLAN

Roof Plan Notes

All Jobs [ACCESS PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS, SUCH AS VENT PIPES, CONDUIT, OR MECHANICAL EQUIPMENT. NFPA 1-11.12.3.2.3.4.]

Attachment Detail

PROVIDE ATTACHMENT NOA

CANNOT USE RAILESS

FLASHKIT PRO ONLY

Electrical Diagram

Second disconnect required if system is separated by gate. Disconnect to be called them

Taps

  • Piercing taps NOT ALLOWED
  • Utilize Polaris Taps
Electrical Diagram Notes

All Jobs [Rapid shutdown to initiate within 30 seconds]

Label Page

FLORIDA - 2020 NFPA 1:11 CAD BLOCK

Label Page Notes

All Jobs [THE LABEL SHALL BE REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVING A MINIMUM HEIGHT OF 3/8 IN. (9.5 MM), IN WHITE ON A RED BACKGROUND. (NFPA 1-11.12.2.1.1.2)]

Custom Placards Required
1
Placards Notes

AC disconnect must have reflective, water resistant sticker/placard

Ground mount

Ground Mount Fencing Required
Mesh/Scrim