Town of Colchester (CT)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL BUILDING CODE
2017 INTERNATIONAL CODE COUNCIL ANSI A 117.1. ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL PLUMBING CODE 2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2020 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- Other (See Submission Notes)
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 133
- Wind Notes
Exposure Category B
- Snow Load
- 30
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
PE Requirements; SE / EE digital stamps on all corresponding PV pages & PE Letter / Calcs. WS 130 MPH GSL 30 PSF
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,Meter Adapter,PV Breaker,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Custom Placards Required
- 1
- Placards Notes
Two map placards
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
For proposed residential uses where the Road edges are cleared of trees, the Front Yard Setback shall be a minimum of two hundred (200) feet and shall include a minimum of one hundred fifty (150) feet of Meadow or active agricultural land measured from the edge of the right of way. Significant trees, ponds or other natural features may also be included in the Front Yard. 2. For proposed residential uses where the Road edges are forested, the Front Yard Setback shall be a minimum of one hundred (100) feet and a minimum forested buffer of fifty (50) feet shall be maintained. This Setback requirement may also be applied to Road edges that are cleared if the applicant demonstrates, through the use of a Landscape plan, prepared by a licensed landscape architect, that a fifty (50) foot forested buffer will be installed at the time of construction. 3. For proposed residential uses utilizing existing Local Roads or proposed new Roads or extensions, the Front Yard Setback shall be seventy-five (75) feet. Ground Screws allowed No grade requirements. Septic documentation is gathered from the Town of Colchester. GM must be above flood level.