Town of Buena Vista (CO)
NEC Code Version2017
Fire Setback Enforced0
Codes
- NEC Code Version
- 2017
- Code List
2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL FIRE CODE 2006 INTERNATIONAL ENERGY CONSERVATION CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Fire setbacks
- Fire Setback Enforced
- 0
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 120
- Snow Load
- 999
- Snow Load Notes
Snow loads are based on zones within the county. Please refer to the PDF "Snow Load Map" uploaded below to determine the snow load for the site. Snow load can be reduced, but not reduced below 35 psf.
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,PV Breaker,Line Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim