City of Pueblo (CO)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2021 INTERNATIONAL FIRE CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL FUEL GAS CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL PLUMBING CODE
2020 NATIONAL ELECTRICAL CODE
- IEBC Accepted
- 1
SolarAPP+ & submittal
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
Structural & loads
- Wind Speed
- 121
- Wind Notes
Exposure Category C
- Snow Load
- 999
- Snow Load Notes
38 PSF for elevations above 7000 ft. 27 PSF for elevations below 7000 ft.
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- No
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Load Side Taps,Meter Adapter
- Supply Tap Neutral Ground Bond Required
- 1
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
- BOS Restrictions
Standard
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard ESS Requirements
- Separate ESS Disconnect Required
- No
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
- Cantilever specs & max. foot spacing need to be highlighted & separately marked on its own page in plans (separate from the attachments/mounting detail page) & structural calcs
- NEED INTERGRATED GROUND AND BONDING CERT LETTER SHEET FOR UNIRAC FOR ALL MODULES.
- Please add mounting system span chart
- Add Rock-It railless UL2703 cert for Rock-It projects to plans
- Notate location of Existing Structure(s) With Distances from Structure(s) to Front, Sides, & Rear Property Lines, and Distance to Other Existing Structure(s) &/or Proposed Structure(s)
- Per AHJ, please use engineer scale on plans instead of architect scale. Plot plans to be drawn to an even numbered engineer scale (1" = 10', 20', 30', etc.) containing the following information on paper no larger than 11" x 17" in size (Note: Arial view maps will not be accepted.)
- Assessor's Parcel Number (http://www.co.pueblo.co.us/cgi-bin/webatrallbroker.wsc/atrpropertysearchall.html (parcel look up))
- Dimensions of the Parcel
- Easements/Building Setback Lines (if applicable)
- Address of Property
- Road Name(s)
- North Arrow
- Designated Scale
- Location AND exterior dimensions of proposed structure(s) with distances from structure(s) to front, sides, & rear property lines and distance to/separation between other existing structure(s) &/or proposed structure(s)
- Project routing sheet from the Pueblo Regional Building Department
- Need product spec sheets for all equipment to be used, roof j-box, conductor/cord grip strain relief, meter, disconnect, etc.
- Cover Page
Standard
- Cover Page Notes
All Jobs [Wind Speed : 120 MPH Exposure Category C // Snow Load: // 38 PSF for elevations above 7000 ft. // 27 PSF for elevations below 7000 ft.]
- Site
Standard
- Site Notes
All Jobs [TOTAL ROOF AREA RIDGE SETBACK CALCS: // TOTAL ROOF AREA: XXXX SQ FT // SINGLE MODULE AREA: XX SQ FT // TOTAL NUMBER OF MODULES // TOTAL AREA OF MODULES: XXXX SQ FT // ROOF COVERAGE XX% // FIRE SPRINKLERS: Y/N // ALL ROOF MOUNTED PANELS WILL BE MOUNTED FLUSH TO THE ROOF.]
- Roof Plan
Standard
- Attachment Detail
* Attachment detail must match actual layout * Plans need an attachment drawing for each array, even if the attachment is the same
- Attachment Detail Notes
All Jobs [MAX CANTILEVER IS 1/3 OF THE ATTACHMENT SPACING // MAX CANTILEVER IS 16" (48" X 1/3 = 16")]
- Electrical Diagram
Line/Load side taps are allowed, however piercing taps are not allowed must be Polaris type taps to be approved.
The conductor size through the production meter is either required to be a minimum of #6 copper or have reducing lugs installed in the jaws of the meter socket. If reducing lugs are to be used, they must be called for in the plan set.
The production meter to be used needs to be highlighted on the product sheet per PRBD policy.
The production meter socket is required to be 200 amp per power company requirements. BHE
Detached structure requires GEC (show on the line diagram)
- Electrical Diagram Notes
If PM is required(BHE) 200A production meter spec sheet line and load wiring must match ELD, Wiring in plan set.
Ex. Eaton 200A PM spec lists #6 line/load wire
- Label Page
Need spec sheets for NEC 690.43 showing compatibility of module to racking
If the panel where are tying in our PV does not have a main breaker, include the following label for that enclosure:
WARNING: This equipment fed by multiple sources total rating of all overcurrent devices excluding the main supply overcurrent device shall not exceed ampacity of the busbar
- Custom Placards Required
- 1
- Placards Notes
If the equipment is not within line of sight with the Utility meter placards are required.
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
Site Plan:
Dimensions of the solar installation and the residence need to be labeled
PL dimensions need to match parcel map
Include easements
11' pier spacing or under is required
Height shown in feet need from ground to highest point of array. (Cannot exceed 6')
NEED SNOW AND WIND LOAD CALCULATIONS PER IronRidge/Nuance, follow AHJ snow load and wind speeds for iron ridge/nuance deliverables; please add iron ridge/nuance pages to plans for GMs.
The dimensions of all structures, both existing and proposed must be shown.
Must label both existing and proposed structures.
Setbacks are required for the existing structures as well as any proposed structures.
The scale must be an ENGINEER scale: 1" = 10', 1"= 20', etc.
For structures over a 1000 sqft, AHJ requires erosion control plan. See attached file for information on how to build one.
- Setback Front Yard
- 10
- Setback Back Yard
- 5
- Setback Side Yard
- 5