City of Lone Tree (CO)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2021 International Building Code and Amendments
2021 International Energy Conservation Code and Amendments
2021 International Mechanical Code and Amendments
2021 International Plumbing Code and Amendments
2021 International Residential Code and Amendments
2021 Fire Code and Amendments
2021 International Fuel and Gas Code
2023 National Electrical Code
2017 Accessibility Code
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 0
- Rough Inspection
- Rough Electrical
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
WIND LOAD: 115 MPH ULT - Exposure C
- Snow Load
- 30
- Snow Load Notes
30 PSF ROOF SNOW LOAD
- Reducible Snow Load Allowed
- 0
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,Meter Adapter,Line Side Taps,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Seismic Design Category: IRC: B Seismic Design Category: IBC: Per chapter 16 CLIMATIC CONDITIONS Heating Degree Days: 6343 Winter Design Temperature: -3 F Summer Dry Bulb 90 F Summer Wet Bulb 59 F Air Freezing Index 867 Mean Annual Temperature 48.1 F Minimum Frost Depth for Foundations 36 inches
- Electrical Diagram
Standard
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim