City of Golden (CO)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 International Building Code 2021 International Energy Conservation Code 2021 International Fire Code 2021 International Fuel Gas Code 2021 International Existing Buildings Code 2021 International Mechanical Code 2021 International Plumbing Code 2021 International Residential Code (Including Appendix Chapter F dealing with radon control for new single family dwellings) 2020 National Electrical Code
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 0
- Rough Inspection
- Rough Electrical
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
At least 3 feet
Structural & loads
- Wind Speed
- 150
- Wind Notes
Exposure Category C
- Snow Load
- 45
- Snow Load Notes
* Ground Snow Load - 42.9 p.s.f. * Wind Load - V ult 150 m.p.h. ~ exposure C * Roof Snow Load - 30 p.s.f. * Frost Depth - 36 inches
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,Meter Adapter,PV Breaker,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
LINE SIDE TAPS: Grid interconnection location shall show AC load panel with backfeed breaker rating (voltage and amperage), panel rating (busbar rating and main breaker rating), and line / load side tap
- Electrical Diagram
Standard
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- No