City of Fort Collins (CO)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL FUEL GAS CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL PROPERTY MAINTENANCE CODE
2023 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Structural & loads
- Wind Speed
- 140
- Wind Notes
- Front Range Gust Map (ASCE 7-10 compatible published by The Structural Engineer's Association of Colorado (dated 10/18/2013)
- Or
- Risk Category ll (most structures): 140mph (Ultimate) exposure B
- Risk Category l: 130mph (Ultimate) exposure B
- Risk Category lll & lV: 150mph (Ultimate) exposure B
- Snow Load
- 30
- Snow Load Notes
- Ground Snow Load: 35 PSF
- Roof Snow Load: Final design roof snow load (including loading and drifting) shall not be less than a uniformly distributed live load of 30 psf.
- Frost Depth: 30 inches
- Seismic Design Category: B
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #6
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Load Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
INFORMATIONAL :Per AHJ plan reviewer: The service is a meter main combo with feed through lugs making this a load side feeder tap, a main breaker will need to be installed in the interior main panel to protect the load side feeders per 705.12(B)(1) Fire setbacks enforced
- Roof Plan
Roof-mounted panels elevated above the roof plane, the support structure and panels shall be designed by a State of Colorado Professional Engineer showing compliance with anchorage to withstand 100 MPH-Exposure B wind loads.
- Electrical Diagram
Centerfed 120%: Not Sure
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
Soil Class: Clay Ground-mounted panels shall be designed by a State of Colorado Professional Engineer showing compliance with anchorage to withstand 100 MPH-Exposure B wind loads
- Ground Mount Requires Soil Sample
- Soil Study