City of Torrance (CA)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2025 CALIFORNIA BUILDING CODE
2025 CALIFORNIA ELECTRICAL CODE
2025 CALIFORNIA FIRE CODE
2025 CALIFORNIA PLUMBING CODE
2025 CALIFORNIA MECHANICAL CODE
2025 CALIFORNIA ENERGY CODE
2025 CALIFORNIA RESIDENTIAL CODE
2025 CALIFORNIA ADMINISTRATIVE CODE
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,MPU,Derate,Derate
- How Many Plansets Required
- 2
- Revision Required
- 1
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- None
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
- MINIMUM 3' SETBACK REQUIRED ON BOTH SIDES OF THE RIDGE, EVEN IF MODULES ARE ONLY LOCATED ON ONE SIDE OF THE RIDGE.
- IF MODULES ARE PLACED ON BOTH SIDES OF A RIDGE, 3' IS REQUIRED ON ONE SIDE & 5' IS REQUIRED ON THE OTHER SIDE OF THE RIDGE
- FLAT ROOFS REQUIRE A 3' PERIMETER SETBACK AROUND ROOF EDGE
Structural & loads
- Wind Speed
- 130
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Structural calcs must provide wind analysis and uplift calcs
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- All Jobs
- Allowed POI
- Load Side Taps,PV Breaker,Line Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
- BOS Restrictions
Standard
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
ESS disconnect required within 6ft of MSP on same wall and not blocked by walls/gates/etc
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- Yes - with dimensions
Plan set
- Plan Set Requirements
- Site
- The AC disconnect must be located within line of sight and within 10 feet of main electrical service.
- ESS SHALL BE LOCATED NOT LESS THAN 3 FEET (914MM) FROM DOORS, WINDOWS, AND OTHER OPENINGS DIRECTLY ENTERING THE DWELLING UNIT.
- Roof Plan
- SPECIFY HEIGHT FROM THE ROOF TO THE TOP OF THE PANEL
- INCLUDE LEADER SHOWING FIRE ACCESS POINT
- Roof Plan Notes
All Jobs [PV SOURCE CIRCUIT CONDUCTORS AND PV OUTPUT CIRCUIT CONDUCTORS SHALL BE PROTECTED FROM PHYSICAL DAMAGE WHEN INSTALLING OUTSIDE OF THE ARRAY. ALL CONDUIT RUNS LEADING TO THE ROOF OR ALONG THE ROOF TO BE RMC INSTEAD OF EMT SO THAT THEY SHALL BE PROTECTED FROM PHYSICAL DAMAGE. (E.G. RMC) CEC 690.31 (A) & (B)]
- Attachment Detail
- Electrical Diagram
AHJ DOES NOT ALLOW EMT (ELECTRICAL METAL TUBING) ONLY RMC (RIGID METAL CONDUIT)
- ALL REFERENCES TO EMT SHALL BE REMOVED AND REPLACED WITH RMC
- Electrical Diagram Notes
All Jobs [PV SOURCE CIRCUIT CONDUCTORS AND PV OUTPUT CIRCUIT CONDUCTORS SHALL BE PROTECTED FROM PHYSICAL DAMAGE WHEN INSTALLING OUTSIDE THE ARRAY. ALL CONDUIT RUNS LEADING TO THE ROOF OR ALONG THE ROOF TO BE RMC INSTEAD OF EMT SO THAT THEY SHALL BE PROTECTED FROM PHYSICAL DAMAGE. (E.G. RMC) CEC 690.31 (A) & (B)]
Battery [ESS SHALL BE LOCATED NOT LESS THAN 3 FEET (914MM) FROM DOORS, WINDOWS, AND OTHER OPENINGS DIRECTLY ENTERING THE DWELLING UNIT.]
- Custom Placards Required
- 1
- Non Standard Planset Requirements
- BOS Elevation
Ground mount
- Ground Mount Fencing Required
- No