City of Laguna Hills (CA)

California Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2023
Fire Code Version2018 Building Code
SolarAPP+ StatusAdopted
Wet Stamps RequiredNone
Fire Setback Enforced1

Codes

NEC Code Version
2023
Fire Code Version
2018 Building Code
Code List

2025 CALIFORNIA BUILDING CODE

2025 CALIFORNIA ELECTRICAL CODE

2025 CALIFORNIA FIRE CODE

2025 CALIFORNIA PLUMBING CODE

2025 CALIFORNIA MECHANICAL CODE

2025 CALIFORNIA ENERGY CODE

2025 CALIFORNIA RESIDENTIAL CODE

2025 CALIFORNIA ADMINISTRATIVE CODE

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

SolarAPP+ Status
Adopted
Any SolarAPP+ Restrictions
1
SolarAPP+ Restrictions
Existing Systems,Trenching,Derate
How Many Plansets Required
3
Revision Required
1
New Planset Required For Module Swap
0

Stamps

Ee Stamp Required On SLD
No
Wet Stamps Required
None
Structural Calculations Required
Yes
Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
1
Setback Notes

Standard

Structural & loads

Wind Speed
110
Wind Notes

Exposure Category C

Snow Load
0
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Structural Notes

Standard

Minimum Ground On Roof
#10

Electrical

Electrical Load Calcs Required
Derates
Allowed POI
Meter Adapter,PV Breaker,Load Side Taps
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
1
BOS Restrictions

Single POI in MSP required.

Battery / ESS

Unique Battery Placards Needed
1
ESS Notes

Battery system must be shown on placard. Battery system needs Battery Disco. No published information about battery placement.

ESS disconnect required within 6ft of MSP on same wall and not blocked by walls/gates/etc

Local disconnect = One disconnect by the batteries (line of sight)

ESS Disconnect = One disconnect by the MSP (line of sight)

If battery is in the garage, provide a fused disconnect at the battery sight.

For garage mounts: Provide a note stating: "A heat detector, paired up with the required smoke detectors throughout the home, shall be installed in the garage for the proposed ESS batteries."

Separate ESS Disconnect Required
Local Disconnect,ESS Disconnect
ESS Elevation Detail Required
Yes - with dimensions

Plan set

Roof Plan

Array roof coverage calcs must include both new and existing PV

Electrical Diagram

120% rule allowed per CEC 705.12(B)(2)(3)(d)

Label Page

FOR BATTERY + EXISTING SYSTEMS:

Include tri-power source label. Sources: Utility Grid, Battery and PV Electric System


R328.11(2): Provide a label on the installed ESS containing the contact information for the qualified maintenance and service providers.


Custom Placards Required
1

Ground mount

Ground Mount Fencing Required
Mesh/Scrim
Compiled from public records, 2026. Requirements change with code cycles and local amendments. Verify with the City of Laguna Hills (CA) building department before you rely on this, and treat it as a research head start, not a ruling. Getting quotes? Run them through the quote checker first.