City of Burbank (CA)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2025 CALIFORNIA BUILDING CODE
2025 CALIFORNIA ELECTRICAL CODE
2025 CALIFORNIA FIRE CODE
2025 CALIFORNIA PLUMBING CODE
2025 CALIFORNIA MECHANICAL CODE
2025 CALIFORNIA ENERGY CODE
2025 CALIFORNIA RESIDENTIAL CODE
2025 CALIFORNIA ADMINISTRATIVE CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Testing
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- Existing Systems,Trenching,Derate
- How Many Plansets Required
- 3
- Revision Required
- 1
- New Planset Required For Module Swap
- 0
Stamps
- Structural Calculations Required
- No
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 110
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,Load Side Taps,Line Side Taps,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
- BOS Restrictions
Standard
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
ESS disconnect required within 6ft of MSP on same wall and not blocked by walls/gates/etc
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- Yes - with dimensions
Plan set
- Roof Plan
STANDARD
- Electrical Diagram
SHOW METER CONNECTIONS (LIKE XCEL) Include a wall mounted knife-blade type dc disconnect between your junction box and inverter. BWP does not accept build-in dc disconnects inside the inverter. On your single line drawing, show the performance meter wiring top to the ac disconnect and bottom to the main service panel.
- Label Page
* On the placards page remove the: "WARNING" INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE" and replace it with: "WARNING" PHOTOVOLTAIC SYSTEM DO NOT RELOCATE THIS BREAKER" * Remove the following label: "Warning: Power Source Output Connection Do Not Relocate This Overcurrent Device". * Signage must be engraved. Remove all references to signage being otherwise marked. * Include values on DC disco labels
- Custom Placards Required
- 1
- Placards Notes
Permanent placards from placard sheet of plans
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim