City of Buena Park (CA)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2025 CALIFORNIA BUILDING CODE
2025 CALIFORNIA ELECTRICAL CODE
2025 CALIFORNIA FIRE CODE
2025 CALIFORNIA PLUMBING CODE
2025 CALIFORNIA MECHANICAL CODE
2025 CALIFORNIA ENERGY CODE
2025 CALIFORNIA RESIDENTIAL CODE
2025 CALIFORNIA ADMINISTRATIVE CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- Storage Systems,Existing Systems,MPU,Derate
- How Many Plansets Required
- 3
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 110
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Snow Load Notes
N/A
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,Load Side Taps,PV Breaker,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
- BOS Restrictions
Standard
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
ESS disconnect required within 6ft of MSP on same wall and not blocked by walls/gates/etc
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Cover Page
provide scope of work (in addition to the title block).
SCOPE OF WORK:
MODULES: (#) MANUFACTURER:MODEL NUMBER
INVERTER(S): (#) MANUFACTURER:MODEL NUMBER
INVERTER LOCATION:
MSP: MANUFACTURER: 200A/200A
SERVICE TYPE: OVERHEAD/UNDERGROUND
ADDITIONAL SERVICES:
STORAGE DETAILS (IF APPLICABLE)
BATTERY QUANTITY: # AND TOTAL STORAGE
BATTER TYPE: MANUFACTURER:MODEL NUMBER
OPERATION MODE: BACKUP/NON-BACKUP
- Electrical Diagram
Only on back feed breaker allowed, if there are multiple sources, they will need to be combined.
- Label Page
If derating, include a placard stating max size main breaker allowed to be installed on this system
Utilize 2017 labels
- Custom Placards Required
- 0
- Non Standard Revision Requirements
If revising the plans prior to the first submission to the AHJ, do not red cloud the changes. The AHJ only wants red clouding for changes after the first submission.
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
provide canopy exterior elevations (provide front Elevation)
opening is not allowed less than 5' from property line. CRC Table R302.1(1)