City of Big Bear Lake (CA)
NEC Code Version2023
Fire Code Version2018 Building Code
SolarAPP+ StatusTargeted
Wet Stamps RequiredNone
Fire Setback Enforced1
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2025 CALIFORNIA BUILDING CODE
2025 CALIFORNIA ELECTRICAL CODE
2025 CALIFORNIA FIRE CODE
2025 CALIFORNIA PLUMBING CODE
2025 CALIFORNIA MECHANICAL CODE
2025 CALIFORNIA ENERGY CODE
2025 CALIFORNIA RESIDENTIAL CODE
2025 CALIFORNIA ADMINISTRATIVE CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 3
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- None
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 125
- Wind Notes
Wind (Nonresidential):
- Risk Category I: Ultimate wind speed of 100 mph
- Risk Category II: Ultimate wind speed of 110 mph
- Risk Categories III & IV: Ultimate wind speed of 115 mph
Risk categories are defined in the California Building Code, Table 1604.5.
Seismic:
- Site-specific seismic accelerations (SDS and SD1) are required.
- Values shall be determined using the USGS Design Maps.
- Calculations must be based on 2012/2015 IBC or ASCE 7-10 values.
- Site Class D shall be used.
- Snow Load
- 100
- Snow Load Notes
- Snow Loads Roof (pf): 100 pounds per square foot (psf)
- Ground (pg): 85 psf (for use in determining snow drift on lower roofs only) Wind Residential Design wind pressure is 85 miles per hour (mph), Exposure C (ASD)
- Reducible Snow Load Allowed
- 0
- Max Attachment Spacing
- 95
- Structural Notes
SE digital stamps on corresponding PV pages & PE Letter / Calcs. WS: 85mph. Exposure C. SL: 5psf
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Load Side Taps,Meter Adapter,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
- BOS Restrictions
Standard
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
ESS disconnect required within 6ft of MSP on same wall and not blocked by walls/gates/etc
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- Yes - with dimensions
Plan set
- Plan Set Requirements
- Attachment Detail
Attachment spacing must not exceed 2' (staggered) due to high snow load
- Electrical Diagram
Centerfed 120% allowed as long as it meets the conditions within the CEC.
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Yes
- Ground Mount Notes
- Fencing required if the circuit conductors are not installed in a raceway and the voltages are greater than 30 volts.