Town of Star Valley (AZ)

Arizona Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2017
Fire Code Version2018 Building Code
Wet Stamps RequiredNone
Fire Setback Enforced1

Codes

NEC Code Version
2017
Fire Code Version
2018 Building Code
Code List

2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL EXISTING BLDG CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL PLUMBING CODE 2017 NATIONAL ELECTRIC CODE

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

Revision Required
0
New Planset Required For Module Swap
0

Stamps

Ee Stamp Required On SLD
No
Wet Stamps Required
None
Structural Calculations Required
No
Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
1
Setback Notes

Standard

Structural & loads

Wind Speed
90
Snow Load
40
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Structural Notes
Structural Engineering Required for manufactured homes
Minimum Ground On Roof
#10

Electrical

Electrical Load Calcs Required
Derates
Allowed POI
Meter Adapter,PV Breaker,Line Side Taps,Load Side Taps
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.91

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Standard

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Plan Set Requirements

Same as Payson-Make sure Star Valley is noted somewhere on documents ; WS is 90/B and snowload is 40 Note the distance of conduit above roof surface, ensure this is consistent on all pages where it is noted. If the ELD shows 7/8 max height, and the general notes says 1 max height, AHJ will issue correction.

Roof Plan

Make sure conduit and J-boxes are shown on roof plan

Electrical Diagram

Show minimum conductor length on SLD, see document in file section Specify AIC rating of PV breaker to comply with APS short circuit current (110.9) Specify AIC rating of Electrical Panel to comply with APS short circuit current (110.9)

Ground mount

Ground Mount Fencing Required
Mesh/Scrim