Town of Queen Creek (AZ)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL RESIDENTIAL CODE AS AMENDED
2021 INTERNATIONAL BUILDING CODE AS AMENDED FOR STRUCTURAL ITEMS NOT COVERED BY THE IRC
2021 INTERNATIONAL FIRE CODE AS AMENDED
2020 NATIONAL ELECTRICAL CODE AS AMENDED
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- Other (See Submission Notes)
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- None
- Structural Calculations Required
- No
- Stamp Location On Plans
- N/A
- Date On Stamps
- N/A
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
* Panels/Modules on residential buildings will roof hips and valleys shall be located not closer than 18" to a hip or valley where panels/modules are to be placed on both sides ofa hip or valley, 2012 IFC Section 605.11.3.2.3.;
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category C
- Snow Load
- 0
- Snow Load Notes
No snow load required
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
- **\- Structural is needed when:** 1. Distributed Weight - If the PV system is greater than 5 pounds per square foot; or 2. Point Load - If the PV system exerts a point load greater than 40 pounds; or 1. _Optional to use either unirac or ironridge design tool for above info_ 3. Age of Home - If the home is more than 35 years old. \- _If structural needed_ : Uplift calcs: provide the required uplift (pounds) from the grouping area and max wind load (ASCE 7-10); identify the pullout (withdrawal) strength per connector and show the required number of connectors (AFPA-NDS-2012); show the selected connector type, size and length (AFPA-NDS 2012)
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates,Load Relocation
- Allowed POI
- Line Side Taps,PV Breaker,Meter Adapter,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 75
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 1
- ESS Notes
Required: Disco and PM between B/U load panel and inverter. Do this on Site Plan and ELD(s): Call out ESS Disco as DER Storage Disconnect . Call out ESS PM as DER Storage Meter . Call out make and model for all Disconnects. Show blades of all Disconnects open to the inverter. No published information about battery placement.
- Separate ESS Disconnect Required
- Local Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Please provide an elevation view of all the equipment being installed on the side of the house
Plans submitted contain AutoCAD SHX Text. Replace with True Type Font or another remedy to ensure removal of all SHX text. Modify` plans and upload reformatted file(s). AHJ also included this, I wanted to include just in case as well ; Additional information about AutoCAD SHX Text is available at ALL PROJECTS MUST flatten and optimize for digital submittal. In AutoCad (https://knowledge.autodesk.com/support/autocad/troubleshooting/caas/sfdcarticles/sfdcarticles/Drawing-text-appears-as-Comments-in-a-PDF-created-by-AutoCAD.html), On the command line, enter EPDFSHX and change the value to 0 (zero). This was per Hollie. NOTE: This was a correction that was issued twice for the same job. We are testing the method. If we get approval for a past project, we'll know if it worked, and this will be standard for Queen Creek 1-line & 3-line required FOR ROOF MOUNTS Show the required Roof access and pathways ; 115 mph, 3 second gust, Exposure B >> Structural is needed when: Distributed Weight - If the PV system is greater than 5 pounds per square foot ; or Point Load - If the PV system exerts a point load greater than 40 pounds ; or Optional to use either unirac or ironridge design tool for above info_ Age of Home - If the home is more than 35 years old. If we are installing a generation panel, provide a spec sheet. All MPUs must have a spec sheet for the new main panel
- Electrical Diagram
Single Line Diagram required
- Non Standard Planset Requirements
- Single Line Diagram,BOS Elevation
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
_**FOR GROUND MOUNTS**_ * Soil Class: Rock * Soil class 2 - soil handles up to 1500 lbs per sq. ft. minimum footing depth of 18" * For Fencing Around GM's - Per 2011 NEC Section 690.31 circuits and others installed in readily accessible locations shall be installed to prevent live parts against accidental contact and prevent physical damage.