Town of Parker (AZ)
NEC Code Version2017
Fire Code Version2018 Building Code
Fire Setback Enforced1
Codes
- NEC Code Version
- 2017
- Fire Code Version
- 2018 Building Code
- Code List
2006 INTERNATIONAL BUILDING CODE 2006 INTERNATIONAL RESIDENTIAL CODE 2006 INTERNATIONAL EXISTING BUILDING CODE 2006 INTERNATIONAL PLUMBING CODE 2006 INTERNATIONAL MECHANICAL CODE 2006 INTERNATIONAL FUEL GAS CODE 2006 INTERNATIONAL FIRE CODE 2006 INTERNATIONAL PROPERTY MAINTENANCE CODE 2005 NATIONAL ELECTRIC CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 95
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Line Side Taps,Load Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Wire size from DER storage disco to DER storage must be 8-AWG. Util PM to be labeled “SG-type Bi-Directional Production Meter” Backup Loads Sub-Panel Meter to be labeled “Blue Face Mono-Directional Production Meter”
- Separate ESS Disconnect Required
- Local Disconnect
- ESS Elevation Detail Required
- No
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim