County of Yavapai (AZ)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2024 INTERNATIONAL BUILDING CODE
2024 INTERNATIONAL RESIDENTIAL CODE
2024 INTERNATIONAL MECHANICAL CODE
2024 INTERNATIONAL PLUMBING CODE
2024 UNIFORM PLUMBING CODE
2024 INTERNATIONAL FUEL GAS CODE
2024 INTERNATIONAL ENERGY CONSERVATION CODE
2024 INTERNATIONAL EXISTING BUILDING CODE
2024 INTERNATIONAL SWIMMING POOL AND SPA CODE
2023 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- Other (See Submission Notes)
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category C
- Snow Load
- 30
- Snow Load Notes
0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Structural Calcs Only Required for the below:
Mounting of ESS equipment on Manufactured
Mobile Homes, Park Model Units and Factory
Built Buildings will require an engineered design
and/or specific approval from the manufacturer.
Calculations must indicate the structure is a
manufacture home and that it can support the
new imposed loads from the ESS
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,PV Breaker,Line Side Taps,Meter Adapter
- Panel Schedule Required
- All Projects
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
ESS no longer allowed within Garage.
Utility PM to be labeled “SG-type Bi-Directional Production Meter” Backup Loads Sub-Panel Meter to be labeled “Blue Face Mono-Directional Production Meter” Provide complete panel schedules and photos of existing dead fronts of panels. Provide equipment storage floor plan indicating required fire separation and ventilation. Code section: Add 2008 Planning and Zoning Ordinance Do not mount equipment on manufactured homes. OK to mount on H-frames. Provide approval letter from APS for existing and proposed roof solar system. Clearly identify what panel the provided panel schedule is for.
- Separate ESS Disconnect Required
- Local Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Site
If project is determined to be in a County of Yavapai flood zone: Itemized project cost with equipment and labor cost must be submitted, Project cost cannot exceed 50% of property valuation.
- Electrical Diagram
Standard
- Electrical Diagram Notes
PCS allowed
- Label Page
Manually create this label. Red label, white big letter ESS with info below.
See
CORRECTION LETTER#1 RES24-003886-staff.pdf
An approved reflective exterior sign, a min. of 6” wide x 4” high, shall be attached to the exterior door of the electrical service panel. The sign shall be of weather resistant construction, with white lettering over a red background, and state ESS in 2” high, the location of the battery below, and the type of battery below that, both in 0.67” high min
- Custom Placards Required
- 0
- Placards Notes
Placards required will be dictated by utility - none required by AHJ.
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
- Ground mount solar panels must meet district building height limitations above natural grade and principal setback requirements.
- Setbacks from property lines are based on lot size. Please refer to the "Setbacks based on lot" file upload to the files below.
- Septic Map Info: Septic Permits - Yavapai, AZ
- Setback Front Yard
- 40
- Setback Back Yard
- 40
- Setback Side Yard
- 20