County of Navajo (AZ)
Codes
- NEC Code Version
- 2014
- Fire Code Version
- 2018 Building Code
- Code List
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL RESIDENTIAL CODE
2018 INTERNATIONAL PLUMBING CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL FUEL GAS CODE
2014 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 2
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 999
- Snow Load Notes
09/20/21 - Per staff, will accept for windspeed but prefers 115 (per 2018 codes); snow load for Heber is 45 for roof pitch up to 4.12; 40 for roof pitch 4.12 and greater Snow load designations anywhere from 20 to 45 lb roof snow load. Ground snow is 30% greater. Check pdf file "Navajo County Additions Dec 2017" for more design info on snow load calcs, electrical and building requirements. http://www.navajocountyaz.gov/LinkClick.aspx?fileticket=OMj2O6NgtXE%3d&portalid=0 (http://www.navajocountyaz.gov/LinkClick.aspx?fileticket=OMj2O6NgtXE%3d&portalid=0) page 7 has snow loads. 3/28/2019
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,Meter Adapter,PV Breaker,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Electrical Diagram
Centerfed 120%: Not Sure AC disconnects required 3-line diagram required, no need for SLD
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- No