City of Surprise (AZ)

Arizona Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2023
Fire Code Version2018 Building Code
SolarAPP+ StatusTargeted
Wet Stamps RequiredDigital Electrical,Digital Structural
Fire Setback Enforced1

Codes

NEC Code Version
2023
Fire Code Version
2018 Building Code
Code List

2024 INTERNATIONAL BUILDING CODE

2024 INTERNATIONAL RESIDENTIAL CODE

2024 INTERNATIONAL FIRE CODE

2024 INTERNATIONAL ENERGY CONSERVATION CODE

2024 INTERNATIONAL EXISTING BUILDING CODE

2024 INTERNATIONAL FUEL GAS CODE

2024 INTERNATIONAL MECHANICAL CODE

2024 INTERNATIONAL PLUMBING CODE

2023 NATIONAL ELECTRICAL CODE

2009 INTERNATIONAL CODE COUNCIL

2024 INTERNATIONAL GREEN CONSTRUCTION CODE

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

SolarAPP+ Status
Targeted
Any SolarAPP+ Restrictions
1
SolarAPP+ Restrictions
MPU,Derate
How Many Plansets Required
Other (See Submission Notes)
Revision Required
1
Rough Inspection
Tile Job
New Planset Required For Module Swap
0

Stamps

Ee Stamp Required On SLD
Yes
Wet Stamps Required
Digital Electrical,Digital Structural
Structural Calculations Required
Yes
Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
1
Setback Notes

Standard

Structural & loads

Wind Speed
120
Wind Notes

Exposure Category B

Snow Load
0
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Minimum Ground On Roof
#10

Electrical

Electrical Load Calcs Required
Derates
Allowed POI
Load Side Taps,PV Breaker,Meter Adapter,Line Side Taps
Panel Schedule Required
Partial Home Backup
Temperature Rating
75
De Rating Ampacity
0.87

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Standard


Add note: The ESS shall be located a minimum of 5 feet from any window, door, or similar opening into the structure. (City of Surprise Local Ordinance 2019-21 1206.4.3.1)


If battery is installed in the garage, add the following note:

A LISTED FIRE DETECTOR SHALL BE INSTALLED ABOVE THE

GARAGE-MOUNTED BATTERY. THIS DETECTOR (SMOKE OR HEAT)

SHALL BE INTERCONNECTED TO THE SMOKE ALARM SYSTEM IN THE

HOME. THE INTERCONNECTION WILL BE TESTED BY CONTRACTOR'S

FIELD TECHNICIAN FOR THE FIRE INSPECTOR IN THE FIELD. (LOCAL

ORDINANCE 2019-21 - 1206.4.6)


A means of disconnect shall be readily accessible and located within sight of the energy storage system.

Separate ESS Disconnect Required
ESS Disconnect,Local Disconnect
ESS Elevation Detail Required
Yes - with dimensions

Plan set

Plan Set Requirements


  • ALL NEW BREAKERS need to be included in the BOM
  • All disconnects included in the plans need to be included in the BOM
  • Provide clear pictures of the main electrical panel the show the rating of the breakers and the labels for the breakers
  • STANDARD HOMES WITH TRUSSES DO NOT NEED STRUCTURAL, RAFTERS OR MANUFACTURED HOMES DO
  • Specs required for ALL equipment, including combiner panels
  • EV chargers need to be on the PV planset. DO NOT create a separate EV charger planset.
  • Include the following the note with the EV charger on the ELD - "EV CHARGER TO BE PERMITTED SEPARATELY"
  • Include the breaker for the EV charger in the load calcs

#NFZ_ALL#

Cover Page


Site Notes

Battery [The ESS shall be located a minimum of 5 feet from any window, door, or similar opening into the structure. (City of Surprise Local Ordinance 2019-21 1206.4.3.1)]

Roof Plan


Roof Plan Notes


Attachment Detail
  • Embedment to be 2.5" inches
Attachment Detail Notes

Roof Mount [All penetrations will be sealed with a listed sealant]

Electrical Diagram
  • EV chargers need to be on the PV planset. DO NOT create a separate EV charger planset.
  • Include the following the note with the EV charger on the ELD - "EV CHARGER TO BE PERMITTED SEPARATELY"
  • Include the breaker for the EV charger in the load calcs
  • If relocating loads, include a list of what loads will be relocated
  • Panel schedule for relocation of loads
  • When providing load calcs, provide a clear photo of the dead front of the panel
Electrical Diagram Notes

Battery [The ESS shall be located a minimum of 5 feet from any window, door, or similar opening into the structure. (City of Surprise Local Ordinance 2019-21 1206.4.3.1)]

Label Page

Derates

  • Derate label must be on label page.
Custom Placards Required
0

Ground mount

Ground Mount Fencing Required
No
Ground Mount Notes

Soil Class - 1500 lbs per square foot - staff

Compiled from public records, 2026. Requirements change with code cycles and local amendments. Verify with the City of Surprise (AZ) building department before you rely on this, and treat it as a research head start, not a ruling. Getting quotes? Run them through the quote checker first.