City of Surprise (AZ)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2024 INTERNATIONAL BUILDING CODE
2024 INTERNATIONAL RESIDENTIAL CODE
2024 INTERNATIONAL FIRE CODE
2024 INTERNATIONAL ENERGY CONSERVATION CODE
2024 INTERNATIONAL EXISTING BUILDING CODE
2024 INTERNATIONAL FUEL GAS CODE
2024 INTERNATIONAL MECHANICAL CODE
2024 INTERNATIONAL PLUMBING CODE
2023 NATIONAL ELECTRICAL CODE
2009 INTERNATIONAL CODE COUNCIL
2024 INTERNATIONAL GREEN CONSTRUCTION CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- Other (See Submission Notes)
- Revision Required
- 1
- Rough Inspection
- Tile Job
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Electrical,Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 120
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,PV Breaker,Meter Adapter,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 75
- De Rating Ampacity
- 0.87
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
Add note: The ESS shall be located a minimum of 5 feet from any window, door, or similar opening into the structure. (City of Surprise Local Ordinance 2019-21 1206.4.3.1)
If battery is installed in the garage, add the following note:
A LISTED FIRE DETECTOR SHALL BE INSTALLED ABOVE THE
GARAGE-MOUNTED BATTERY. THIS DETECTOR (SMOKE OR HEAT)
SHALL BE INTERCONNECTED TO THE SMOKE ALARM SYSTEM IN THE
HOME. THE INTERCONNECTION WILL BE TESTED BY CONTRACTOR'S
FIELD TECHNICIAN FOR THE FIRE INSPECTOR IN THE FIELD. (LOCAL
ORDINANCE 2019-21 - 1206.4.6)
A means of disconnect shall be readily accessible and located within sight of the energy storage system.
- Separate ESS Disconnect Required
- ESS Disconnect,Local Disconnect
- ESS Elevation Detail Required
- Yes - with dimensions
Plan set
- Plan Set Requirements
- ALL NEW BREAKERS need to be included in the BOM
- All disconnects included in the plans need to be included in the BOM
- Provide clear pictures of the main electrical panel the show the rating of the breakers and the labels for the breakers
- STANDARD HOMES WITH TRUSSES DO NOT NEED STRUCTURAL, RAFTERS OR MANUFACTURED HOMES DO
- Specs required for ALL equipment, including combiner panels
- EV chargers need to be on the PV planset. DO NOT create a separate EV charger planset.
- Include the following the note with the EV charger on the ELD - "EV CHARGER TO BE PERMITTED SEPARATELY"
- Include the breaker for the EV charger in the load calcs
#NFZ_ALL#
- Cover Page
- Site Notes
Battery [The ESS shall be located a minimum of 5 feet from any window, door, or similar opening into the structure. (City of Surprise Local Ordinance 2019-21 1206.4.3.1)]
- Roof Plan
- Roof Plan Notes
- Attachment Detail
- Embedment to be 2.5" inches
- Attachment Detail Notes
Roof Mount [All penetrations will be sealed with a listed sealant]
- Electrical Diagram
- EV chargers need to be on the PV planset. DO NOT create a separate EV charger planset.
- Include the following the note with the EV charger on the ELD - "EV CHARGER TO BE PERMITTED SEPARATELY"
- Include the breaker for the EV charger in the load calcs
- If relocating loads, include a list of what loads will be relocated
- Panel schedule for relocation of loads
- When providing load calcs, provide a clear photo of the dead front of the panel
- Electrical Diagram Notes
Battery [The ESS shall be located a minimum of 5 feet from any window, door, or similar opening into the structure. (City of Surprise Local Ordinance 2019-21 1206.4.3.1)]
- Label Page
Derates
- Derate label must be on label page.
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
Soil Class - 1500 lbs per square foot - staff