City of Glendale (AZ)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2024 INTERNATIONAL BUILDING CODE
2024 INTERNATIONAL RESIDENTIAL CODE
2024 INTERNATIONAL MECHANICAL CODE
2024 INTERNATIONAL PLUMBING CODE
2024 INTERNATIONAL ENERGY CODE
2024 INTERNATIONAL FUEL CODE
2024 INTERNATIONAL FIRE CODE
2023 NATIONAL ELECTRIC CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- None
- Structural Calculations Required
- Yes
- Ee Stamp Notes
SE / EE digital stamps on all PV pages 1-7a & PE Letters / Calcs.
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Snow Load Notes
NO
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,PV Breaker,Meter Adapter,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.87
Battery / ESS
- Unique Battery Placards Needed
- 1
- ESS Notes
Add note or diagram showing that ESS units installed outdoors or on exterior walls must be located not less than 3 feet (914 mm) from doors and windows directly entering the dwelling unit, except where smaller separation distances are permitted by UL 9540 listing and manufacturer's installation instructions.
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Include span charts to justify attachment span
- Site
One AC disconnect must be w/in 10 ft of the SES. On site plan, 24/7 access AC disconnect will be labeled utility, while on ELD AC disconnect closest to MSP will be labeled utility.
- Site Notes
All Jobs [THE PHOTOVOLTAIC SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE AND PLAQUES PER NEC 705- 10, 690-17, AND 690-64(b)(5).]
Battery [ESS units installed outdoors or on exterior walls must be located not less than 3 feet (914 mm) from doors and windows directly entering the dwelling unit, except where smaller separation distances are permitted by UL 9540 listing and manufacturer's installation instructions.]
- Attachment Detail
Call out sealant and flashing (for tile projects only) Geocel 2300 cpw tripolymer sealant"
- Electrical Diagram
Will not allow tie-ins via 6-handle rule. Preferred POI would be MSA or MPU
- Electrical Diagram Notes
Derates [Main Breaker to be downsized]
Will not allow tie-ins via 6-handle rule. Preferred POI would be MSA or MPU
- Custom Placards Required
- 0
- Non Standard Revision Requirements
Will not allow tie-ins via 6-handle rule. Preferred POI would be MSA or MPU
Ground mount
- Ground Mount Fencing Required
- Yes
- Ground Mount Notes
_**GROUND MOUNT**_ * **1200 psf soil class 18" minimum footing depth** * **Soil Class: Clay**