Solar Sanity Checksolar, decoded Independent. Nothing you type leaves your browser.

City of Berryville (AR)

Arkansas Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2017
Fire Code Version2015 Building Code
SolarAPP+ StatusTargeted
Fire Setback Enforced1

Codes

NEC Code Version
2017
Fire Code Version
2015 Building Code
Code List

2012 ARKANSAS FIRE PREVENTION CODE 2017 NATIONAL ELECTRIC CODE 2006 ARKANSAS STATE FUEL GAS CODE 2006 ARKANSAS STATE PLUMBING CODE 2010 ARKANSAS STATE MECHANICAL CODE 2014 ARKANSAS STATE ENERGY C

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

SolarAPP+ Status
Targeted
Any SolarAPP+ Restrictions
1
SolarAPP+ Restrictions
MPU,Derate
How Many Plansets Required
1
Revision Required
0
New Planset Required For Module Swap
0

Fire setbacks

Fire Setback Enforced
1
Setback Notes

One side of each plane must have a 3 foot fire setback, as well as 3 feet from all ridges.

Structural & loads

Wind Speed
90
Snow Load
10
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Minimum Ground On Roof
#10

Electrical

Allowed POI
Line Side Taps,Load Side Taps,PV Breaker,Meter Adapter
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.91

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Standard

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Ground mount

Ground Mount Fencing Required
Mesh/Scrim
Compiled from public records, 2026. Requirements change with code cycles and local amendments. Verify with the City of Berryville (AR) building department before you rely on this, and treat it as a research head start, not a ruling. Getting quotes? Run them through the quote checker first.